Showing results: 511 - 525 of 2604 items found.
-
Model TRMT MULTIFUNCTION POWER -
Kusam Electrical Industries Limited
• Easy Installation & Space saving.• Simultaneous detect & display : - Individual Phase to neutral Voltage - Individual Phase Current - Individual Phase watt. - Frequency - Phase to Phase Voltages. - - Power Factor - - Total Watt - - Total Var
-
Knick Elektronische Messgeräte GmbH & Co. KG.
Especially to accurately measure large DC currents via shunt resistors, ie for making isolated detection of mV voltage on shunts. Variants with calibrated range selection. Working voltage up to 3600 V AC / DC.
-
KT6202 -
Ketai instrument (kunshan) Ltd.
3 1/2 digits self-changing range digital multimeter, display reading 1999low voltage promptAC/DC voltage can be measured 0~500VAC/DC current can be measured 0~10Aresistance measurement can be measured 0~20MΩcontinuity test and diode test
-
66332A -
Keysight Technologies
The Keysight Mobile Communications DC Source 663xx series offers several features ideal for testing wireless and battery powered devices. Excellent voltage transient response ensures maximum test-system throughput by minimizing device shutdowns due to significant voltage drops in the test wiring. Built-in advanced measurement system to accurately measure battery current drains when the device operates in different modes and a Keysight-developed feature that enables cellular telephone manufacturers to detect permanently and intermittently open-sense wire connections. The Keysight 66332A Dynamic Measurement dc Source provides dynamic measurement and analysis of voltage and current waveforms. It is ideal for testing digital wireless communications products/components because it not only provides the power for testing, but also performs the peak current measurements required to characterize the pulsed current demands of these products.
-
E3649A -
Keysight Technologies
Output ratings (@ 0C to 40C) 2 outputs Range 1: 0 to 35 V / 1.4 ARange 2: 60 V / 0.8 A Programming accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 10 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.2% + 10 mARipple & noise 20 Hz to 20 MHz Normal Mode Voltage: <8 mVpp / 1 mVrms Normal Mode Current: <4 mArms Common Mode Current: <1.5 uArms Readback accuracy (@ 25C 5C), (% output + offset)Voltage: <0.05% + 5 mV (<0.1% + 25 mV for output 2 of E3646/47/48/49A)Current: <0.15% + 5 mA (<0.15% + 10 mA for output 2 of E3646/47/48/49A)
-
6522 -
Peaceful Thriving Enterprise Co Ltd
The multi-function automobile tester has LCD display to indicate the measured result. It has polarity detection with the LEDs for a positive and negative indication of DC voltage. For auto use, the functions included the measurement of DC voltage and current, signal frequency and max/min voltage, resistance, temperature and power providing testing.
-
MP-50 -
FRANKONIA GmbH
The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.
-
Ametek Scientific Instruments
Potentiostats control a voltage and measure a resulting current. The Control Amplifier outputs power to the counter electrode (also called auxiliary electrode). A feedback loop is established to control the cell potential between the reference and working electrode. This voltage is measured by the input electrometer, that has a high impedance. This current is then measured between the working and counter electrodes while this potential is maintained at the working electrode and reference electrode.
-
TCS-1 -
JFM Engineering
The TCS-1 Trickle Charger is a low current, constant current/constant voltage charger It can be used to trickle charge Nickel-Cadmium and Lead-Acid batteries. Its primary use is to maintain the batteries at full charge while the batteries are in storage (to compensate for the battery self-discharge). Adjustable float voltage and maximum charging current. Usable on batteries up to 100A-Hr The TCS-1 can also be used as a full charger for batteries of up to 5.0A-hr (@ C/10).
-
Algodue elettronica
Additional voltage and current measurement channels in comparison with other standard three-phase devices.Current inputs for CTs or for clamps to grant an accurate current measurement.Continuous monitoring of the power quality and Class A certified measurements for voltage characteristics.Simultaneous recording of events, Min/Avg/Max LOG and energy counters.Several possibilities for instrument data transmission: Ethernet, Modbus TCP, 3G network.User-friendly instrument web interface with multilingual pages.
-
Digatron Power Electronics
Electronic loads are required for testing fuel cells such as PEMFC, AFC, PAFC, MCFC, SOFC. These electronic loads are designed either in IGBT technology with power, current and voltage ranges according to specific requirements or in transistor technology. Electronic loads in IGBT technology are designed for high voltage ranges up to 900 V, current ranges up to 1000 A, and power ranges up to 480 kW.
-
AMPI-530 -
Amperis sl
Measurement of short-circuit loop ; Testing of differential, general and selective protections for differential current ; Measurement of insulation resistance ; Up to 10GΩ ; Voltages: 50 V, 100 V, 250 V, 500 V, 1000 V ; Measurement of earth resistance ; Bi-directional continuity test on PE cables, phase sequence ; Measurement and recording of voltage, frequency, alternating current, cosϕ, power, harmonics and THD
-
N8740A -
Keysight Technologies
Keysight's basic DC power supplies offer essential features for a tight budget. The Keysight N8740A is a 150 V, 22 A, 3300 W, single output power supply in a small 2U package. It offers flexible AC input options, analog/resistance control of output voltage and current, as well as parallel and series connection of multiple supplies to achieve more output current or voltage respectively.
-
N8742A -
Keysight Technologies
Keysight basic DC power supplies offer essential features for a tight budget. The Keysight N8742A is a 600 V, 5.5 A, 3300 W, single output power supply in a small 2U package. It offers flexible AC input options, analog/resistance control of output voltage and current, as well as parallel and series connection of multiple supplies to achieve more output current or voltage respectively.
-
HCL-5000KN+ -
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Wide AC current measurements for 0.01A~500A.・Easy operation, Push to Open and Pull to Disconnect Mechanism.・Safe AC current measurements for high voltage circuit (AC80 to 7000V).・Auto power off function and Splash proof structure.